Honeywell 05701-A-0330 System 57 High Integrity Safety Relay Output Card (SIS ESD Interlock Module)



  • Product Code: 05701-A-0330
  • Availability: In Stock

Purchase Attributes:Original, Brand New

Service Attributes

▷ Stock & Logistics:Fast Delivery

▷ After-sales Guarantee:12 Months Warranty

▷ Online Customer Service:24 Hours Online Support

▷ Product Advantages:Competitive Price,  Long Service Life

Application Attributes:Honeywell 05701-A-0330 System 57 High Integrity Safety Relay Output Card (SIS ESD Interlock Module)

Honeywell 05701-A-0330 System 57 High Integrity Safety Relay Output Card (SIS ESD Interlock Module)
Manufacturer: Honeywell Process Solutions
Model: 05701-A-0330 (System 57 Series Safety I/O Card)
Matching System: Honeywell System 57 High Integrity SIS Safety Interlock System; Not compatible with TDC3000 / Experion PKS C300 DCS
Type: Rack-mounted 8-channel safety relay output card, SIL2 certified per IEC61508, fail-safe design, heavy-duty SPCO relay contacts onboard
Core Function: Convert safety logic commands from System57 controller to hard relay contacts; drive ESD shutdown valves, alarm horns, strobe lights, exhaust fans, safety interlock loads; per-channel circuit self-diagnosis, contact wear monitoring, open/short fault feedback to safety CPU; applied in refinery, power plant, offshore platform SIS safety cabinet
1. Product Overview
05701-A-0330 is the core safety output module of Honeywell System 57 SIS platform, dedicated to safety instrumented system emergency interlock execution. It integrates 8 independent industrial safety SPCO relays directly on PCB, no external FTA relay terminal board required; front orange terminal block directly connects field safety equipment loads. Adopts fail-safe de-energized trip logic: when card power loss, communication failure or internal circuit fault, all relays drop to safe state (normally closed contact closed) to trigger emergency shutdown, meeting safety instrument system single fault tolerance requirements. Full channel self-test function: real-time monitor relay coil circuit, contact open/short, load loop fault, fault signal uploaded to System57 safety controller for alarm recording. Dual redundant communication bus with main controller to avoid single point of failure. 24VDC backplane power supply, wide temperature industrial hardware, heavy 10A/250VAC contact rating can directly drive valve solenoids, sound-light alarm devices without intermediate relays. Standard System57 3U rack slot installation, hot-swappable for online maintenance without full rack shutdown.
2. Complete Technical Specifications
• Channel Quantity: 8 independent safety relay output channels
• Relay Contact Type: SPCO single-pole changeover (NO / NC / COM)
• Contact Load Rating: Max 10A @ 250VAC resistive load per channel
• Fail-Safe Logic: De-energize to trip; loss of power = all relays de-energized, NC contact closed for ESD trigger
• Safety Integrity Level: IEC61508 SIL2 certified safety circuit
• Supply Voltage: 24VDC rack backplane, operating range 18~32VDC
• Channel Diagnostics: Relay coil open, contact short/open, field load loop fault detection per channel
• Isolation: Channel-to-backplane 1000VAC galvanic isolation, each relay independent isolation circuit
• Surge & ESD Protection: ±15kV contact ESD, 2kV line surge suppression on all field terminals
• Hot Swap Support: Hot plug/unplug without rack power shutdown
• Communication: Dual redundant serial safety bus to System57 main controller
• Operating Temperature: -40℃ ~ +70℃ industrial cabinet environment
• Storage Temperature: -40℃ ~ +85℃
• Humidity: 5% ~ 95% RH non-condensing
• Mechanical Size: 3U rack card, single slot for System57 standard cabinet
• Certification: CE, UL508, IEC61508 SIL2 safety certification
3. Hardware Structure Composition
1. 8 groups of industrial safety SPCO relays mounted on PCB, independent drive circuit for each channel
2. Large orange screw terminal block: field load wiring terminals for 8 relay channels (NO/NC/COM)
3. D-SUB 15pin rear connector: dual redundant safety communication bus to rack backplane
4. Multi-color front panel LED: RUN, FAULT, COMM, channel relay status indicator
5. On-board diagnostic ASIC for real-time loop fault monitoring of each relay channel
4. Core Industrial SIS Application Scenarios
• Petrochemical refinery SIS ESD cabinet: emergency shutdown valve solenoid drive, high/low pressure interlock relay output
• Thermal power plant boiler & turbine safety system: flame trip, emergency trip alarm horn & vent fan control
• Offshore oil & gas platform safety instrument cabinet: fire & gas detection alarm strobe and isolation valve output
• Chemical plant reactor safety interlock system, toxic gas exhaust fan safety control relay card